Product Details:
Payment & Shipping Terms:
|
Power Supply: | 220V / 380V | Operating Mode: | Automatic And Manual Working Modes Are Available |
---|---|---|---|
Pump Protection: | Protection Functions Such As Overload, No Load, And Ultra Low Voltage | Signal: | AC Digital Signal Detection Function, |
Control Distance: | The Longest Control Distance Is 500 Meters | Operating: | Easy To Debug And Easy To Operate |
High Light: | automatic water level controller,automatic water pump motor controller |
Self-contained overload protection automatic water pump controller
The automatic pump controller is simple and efficient. When the pump is started to pump water, it is often forgotten to shut it down, resulting in waste of electricity and water. The installation of the fully automatic pump is simple and efficient to solve the start and stop of the pump. When the pool is filled with high water level, the pump water supply is stopped by the sensor signal. When the pool is at low water level, the sensor signal starts the pump to pump water.
The automatic water pump controller adopts digital core with overload, no load and ultra low voltage protection. The upper and lower levels and pressure are automatically controlled in one.
Can be connected to float control, pressure gauge control and probe sensor control
Selection Guide
Inverter Model | Suitable motor | Pump quantity | Breaker |
Single phase 220V | |||
PC1-S2-1500 | 0.37~1.5kW | 1 | No |
PC1-S2-2200 | 0.37~2.2kW | 1 | No |
PC2-S2-2200B | 0.37~2.2kW | 2 | Build-in |
Three phase 220V | |||
PC1-T2-2200 | 0.37~2.2kW | 1 | No |
PC1-T2-2200B | 0.37~2.2kW | 1 | Build-in |
PC2-T2-2200B | 0.37~2.2kW | 2 | Build-in |
PC1-T2-4000 | 1.0~4.0kW | 1 | No |
PC1-T2-4000B | 1.0~4.0kW | 1 | Build-in |
PC2-T2-4000B | 1.0~4.0kW | 2 | Build-in |
PC1-T2-7500B | 1.0~7.5kW | 1 | Build-in |
PC2-T2-7500B | 1.0~7.5kW | 2 | Build-in |
Three phase 380V | |||
PC1-T4-2200 | 0.37~2.2kW | 1 | No |
PC1-T4-2200B | 0.37~2.2kW | 1 | Build-in |
PC2-T4-2200B | 0.37~2.2kW | 2 | Build-in |
PC1-T4-4000 | 1.0~4.0kW | 1 | No |
PC1-T4-4000B | 1.0~4.0kW | 1 | Build-in |
PC2-T4-4000B | 1.0~4.0kW | 2 | Build-in |
PC1-T4-7500 | 1.0~7.5kW | 1 | No |
PC1-T4-7500B | 1.0~7.5kW | 1 | Build-in |
PC2-T4-7500B | 1.0~7.5kW | 2 | Build-in |
PC1-T4-11000B | 2.2~11kW | 1 | Build-in |
PC2-T4-11000B | 2.2~11kW | 2 | Build-in |
PC1-T4-15000B | 2.2~15kW | 1 | Build-in |
PC2-T4-15000B | 2.2~15kW | 2 | Build-in |
Technical Specifications
Item | Technical Index | Specification |
Input | Input voltage | 1AC 220V±15%, |
3AC 220V±15% | ||
3AC 380V±15% | ||
Input frequency | 50/60Hz±5% | |
Self-consumed power | Standby state | <3.5W |
Running state | <4.5W | |
Default setting | No-load current | 0.0A |
No-load restart time | 30 minutes | |
Control distance | Maximum control distances | 500m |
Overload protection time | Inverse time limit (±15% time error |
120% / 50s |
150% / 30s | ||
200% / 15s | ||
300% / 6s | ||
500% / 1s |
Description of the display and operation area
Contact Person: Tim
Tel: +8618665335699