Product Details:
Payment & Shipping Terms:
|
Intelligent Control: | Speed Sensorless Open Loop Vector Control | V/F: | Multi-point V/F Curve Setting |
---|---|---|---|
High Reliability: | Mature And Reliable Drive, Protection Circuit Design, Anti-interference Design | PID: | Built-in PID With 16-speed Control |
Self-study: | Motor Parameter Rotation, Stationary Self-learning | Exterior: | Small Size Reduces Installation Space |
High Light: | single phase motor drive,single phase frequency inverter |
220V~240V Single Phase Variable Frequency Drive 1AC 0.4KW~1.5KW
With open-loop vector and V/F control, high-performance current vector control technology can realize asynchronous motor control with its own 485 communication port. The built-in PID makes it easy to implement a closed-loop process control system that can operate up to 16 speeds. With swing frequency and fixed length control, it can be used for driving of textile, paper, wire drawing, packaging, food and various automatic production equipment.
no. | Items | KD100 |
1 | Reliable hardware | Only first-class componens are built-in. |
2 | Rubust design | All the components are selected at higher size. |
3 | PCB aging test | 100% test, 45°C, 12 hours. |
4 | Finished products aging test | 100% test, 50°C, 24 hours. |
5 | Loading test | Two times, 100%: |
1. After manufacturing. | ||
2. After aging test. | ||
6 | Grouped pulse testing | Without failure under 4500V (better EMC performance). |
7 | Electrostatic testing | 1. Noncontact conditions -- without failure under 10000V. |
2. Under contact condition -- without failure under 5000V. | ||
8 | Unqualification during production | <0.03% |
9 | Total failure ratio at industrail sites | <0.5% |
10 | High overload capacity | 150% / 60s, 180% / 10s, 200% /1s |
11 | Smart start / stop mode | Acceleration / Deceleration time can be set as 0.0s, the inverter start and stop the motor as fast as possible without failure. |
12 | S ccure Acceleration / Deceleration mode | Better start stop performance. |
13 | Big start torque | 0.5Hz/150% (V/f), 1Hz/150% (SVC) |
14 | Better stop performance | 1. Current is limited smoothly while stoping; |
2. Stops smoothly in very short time for heavy load applications. | ||
15 | Better input voltage flexibility | -15%~+15% without failure. |
Model | Motor | Rated Input Current (A) | Rated Output Current (A) | |
KW | HP | |||
1AC 220V±15% | ||||
KD100-00040S2 | 0.4 | 0.5 | 5.4 | 2.3 |
KD100-00075S2 | 0.75 | 1 | 8.2 | 4 |
KD100-00150S2 | 1.5 | 2 | 14 | 7 |
Contact Person: Tim
Tel: +8618665335699