Product Details:
Payment & Shipping Terms:
|
High Overload Capacity: | 150% / 120s, 160% / 60s, 180% / 10s, 200% /1s | Braking Method: | With DC Braking, Resistance Energy Braking |
---|---|---|---|
PCB Protection: | Spray Three Anti-paint To Protect The Circuit Board Intelligently And Efficiently | Smart Start/sttop: | Reliable Speed Tracking Restart Performance |
Starting Torque: | 0.5Hz/150% Torque, Speed Ratio 1:100, Dynamic Response <20ms, Steady Speed Accuracy ±0.2% | Design: | Modular Design, Compact Structure, Easy Maintenance And Enhanced Product Interchangeability |
High Light: | ac motor vfd,variable ac drive |
High Performance AC Variable Frequency Drive 3AC 380V~460V 315KW 355KW 400KW
The inverter-controlled speed control system is based on advanced technical control theory and intelligent control means to achieve extremely high responsiveness and stability.
With its unique super performance and superior cost performance, the inverter meets the performance requirements of the spindle with wide speed range, high speed stability, strong overload capability, large
low speed torque and short acceleration and deceleration time.
Small size, high precision, easy operation, high reliability, multi-layer protection of equipment, better than any previous speed regulation mode.
Item | Technical Index | Specification |
Input | Input voltage | 3AC 380~460V±15% |
Input frequency | 50/60Hz±5% | |
Output | Output frequency | 0~6000Hz |
Output voltage | 0~rated input voltage | |
Control Features | Control mode | V/f control |
Sensorless vector control | ||
Torque control | ||
Operation command mode | Keypad control | |
Terminal control | ||
Serial communication control (Modbus) | ||
Frequency setting mode | Digital setting, analog setting, pulse frequency setting, serial communication setting, multi-step speed setting & simple PLC, PID setting, etc. These frequency settings can be combinated & switched in various modes. | |
Speed control precision | ±0.5% (SVC) | |
Starting torque | 0.5Hz/180% (SVC); 1Hz/150% (V/f) | |
Carrier frequency | temperature and load characteristics 0.5~16.0kHz, automatically adjusted according to | |
Frequency accuracy | Digital setting: 0.01Hz | |
Analog setting: maximum frequency ×0.05% | ||
Acceleration/deceleration mode | Straight line/S curve; four kinds of acceleration/deceleration time, range: 0.0s~65000s | |
Torque boost | Automatically torque boost; manually torque boost: 0.1%~30.0 | |
Braking unit | build-in standard. | |
DC braking | DC braking when starting and stopping | |
DC braking frequency: 0.0Hz~maximum frequency | ||
Braking time: 0.0s~25.0s | ||
Jog operation | Jog operation frequency: 0.0Hz~maximum frequency | |
Jog acceleration/deceleration time: 0.1s~3600.0s | ||
Simple PLC & multi-step speed operation | It can realize a maximum of 16 multi-step speeds running via the built-in PLC or control terminal. | |
Built-in PID | Built-in PID control to easily realize the close loop control of the process parameters (such as pressure, temperature, flow, etc.) | |
Automatic voltage regulation | Keep output voltage constant automatically when input voltage fluctuating | |
Control Function | Torque control | Torque control without PG |
Wobble frequency control | Multiple triangular-wave frequency control, special for textile | |
Timing/length/counting control | Timing/length/counting control function | |
Over-voltage & over-current stall control | Limit current & voltage automatically during the running process, prevent frequent over-current & over-voltage tripping | |
Fault protection function | Comprehensive protections include over-current, over-voltage, under-voltage, overheating, default phase, overload, shortcut, etc., can record the detailed running data while failures happen. | |
Input/output terminals | Input terminals | Programmable digital input: 7 multifunctional inputs, one can be work as high speed pulse input.3 programmable analog input:AI1, AI2, AI3: 0~10V / 4~20mA |
Output terminals | 2 relay outputs, | |
2 open collector outputs, | ||
2 anaalog outputs, 0~10V / 4~20mA | ||
Communication terminals | Build-in standard RS485 communication interface, support MODBUS-RTU communication protocol | |
Environment | Ambient temperature | -10~50°C, without direct sunshine. |
Humidity | 90%RH or less (non-condensing) | |
Altitude | ≤1000M: output rated power, >1000M: output derated | |
Storage temperature | -20~60°C | |